Standard
RE2020
System Type
New-building regulation
Steel Envelope Target
Full Thermal Decoupling
Airtightness Benchmark
n50 <= 0.60 h⁻¹
Verification Date
2026-09-12
New-building regulation

RE2020 Energy Standards & Steel Frame | Passive Steel Homes

France’s new-building regulation addresses energy, life-cycle carbon and summer comfort. Applicable requirements depend on project scope and timing.

RE2020 Performance Benchmarks vs Standard Building
ISO / EN Verified
Heating Demand Standard Building: ~90 kWh ≤ 15 kWh (SerVilla) Airtightness (n50) Code Limit: 2.50 h⁻¹ 0.35 h⁻¹ (SerVilla) Window Uw (W/m²K) Double Glazing: 1.30 W/m²K 0.78 W/m²K (3 Cam) Thermal Bridge (Ψ) Concrete Beam: ~0.45 W/mK ≤ 0.010

RE2020 in Steel Frame Construction

France’s new-building regulation addresses energy, life-cycle carbon and summer comfort. Applicable requirements depend on project scope and timing.

Key Questions for Project Evaluation

Who supplies environmental product data for steel, foundation and other materials? Who coordinates the complete building assessment?

Applicable Countries & Adoption for RE2020

European countries where this standard serves as a statutory code, subsidy benchmark, or accredited green label:

2 Countries Mapped

France

Verified Framework
Mandatory National Building Code
Local Framework: RE2020 Environmental & Energy Regulation
View France Guide

Monaco

Edition / Verification
Aligned Environmental Regulation
Local Framework: Réglementation Énergétique des Bâtiments (RE2018)
View Monaco Guide

Performance Benchmarks & Criteria for RE2020

New-building regulation
Performance Parameter Benchmark Target Steel Envelope Methodology
Bioclimatic Need (Bbio) Bbio ≤ Bbio_max (-%30 vs RT2012) South-facing solar optimization + compact envelope geometry
Primary Energy (Cep / Cep,nr) Cep ≤ Cep_max (kWh/m²a) Fossil-free building services; inverter air-to-water heat pump
Embodied Carbon (Ic_construction) ≤ Decreasing French Regulatory Threshold CFS weight reduction slashes foundation concrete volume & water
Summer Overheating Degree-Hours (DH) DH ≤ 350 – 1250 Derece-Saat Integrated external blinds & high-density rockwool phase shift
Air Permeability (Q4Pa-surf) ≤ 0.60 m³/(h·m²) Aero-tight membranes & factory-tested penetrations

Delivery Packages Compatibility for RE2020

Required procurement scope and on-site interfaces to secure compliance with this standard:

Explore All Packages

P1 Structural Frame

Incomplete (Requires Envelope Package)

Supplies precision CFS steel frame and certified Eurocode statics dossier. Thermal insulation, airtight membranes, and high-performance fenestration must be procured and executed by your local site contractor.

P2 Frame + Cavity Insulation

Partial Shell (Requires Exterior EWI)

Includes structural steel studs, cavity rockwool infill and exterior structural sheathing. Meeting the stringent benchmark U-values of this standard requires additional continuous exterior rockwool wrap on site.

P3 Weather-Tight Envelope

Recommended / Certified Envelope Guarantee

The SWEET SPOT for Passive House & statutory low-energy standards. Features continuous exterior insulation wrap (U <= 0.11-0.14 W/m²K), certified triple-glazed fenestration, and airtight junction details securing n50 <= 0.60 h⁻¹.

P4 Complete Turnkey Kit

Fully Compliant / Complete Kit

Includes full P3 thermal envelope plus certified 85%+ MVHR ventilation unit, heat pump readiness, interior drywall lining assemblies, and sanitary/electrical rough-in components for 100% turnkey compliance.

STATE SUBSIDIES & GREEN FINANCE

France Eco-PTZ Zero-Interest Loan & Property Tax Exemptions

€50,000 Interest-Free Loan + Up to 5-Year Property Tax Exemption

Projects exceeding RE2020 energy and LCA carbon benchmarks can secure interest-free Eco-PTZ funding and up to 5-year local property tax (Taxe Foncière) exemptions in participating French communes.

Calculate Subsidy & Costs Construction Cost Guide

Certification & Verification Roadmap for RE2020

01
Dynamic Energy Simulation

PHPP or statutory calculation prepared with plot coordinates, solar azimuth, and local weather files.

02
Component Optimization

Target U-values specified with exterior rockwool thickness and triple-glazed warm-edge fenestration.

03
On-Site Blower Door Test

ISO 9972 pressure test and IR thermography physically verify airtightness threshold n50 <= 0.60 h⁻¹.

04
Accredited Certification

Third-party certified audit dossier submitted for official energy efficiency and green mortgage registration.

Why Cold-Formed Steel for RE2020?

Dimensional Stability

Steel frame does not shrink, twist or warp, ensuring airtight seals and tape junctions remain permanently intact.

CAD/CAM Precision

Windows and panel interfaces are roll-formed to 0.5 mm tolerance, preventing unplanned thermal leaks on site.

100% Inorganic

Galvanized steel is impervious to rot, mold, fungi and termites, securing building biology credentials.

Consult on RE2020 Compliance for Your Plot

Review required U-values, envelope assemblies and delivery package scopes tailored to RE2020.

Consult via WhatsApp

Explore Other Model Concepts

Compare alternative footprints, storey options and spatial arrangements.

Important Note: Veranda, garage, terrace, pool, BASEMENT FLOOR, etc. are NOT included in areas & PRICES. Semi-detached / twin models: 1 unit basis.
Model 25-1003 — 99 m², 1 storey
Model 25-1003 Farmhouse & Ranch

Model 25-1003 • 99 m²

Model 25-1003 — 99 m², 1 storey

1 Storey
2 Bedrooms
1 Garage
Model 25-1004 — 114 m², 1 storey
Model 25-1004 American Style

Model 25-1004 • 114 m²

Model 25-1004 — 114 m², 1 storey

1 Storey
3 Bedrooms
1 Garage
Model 25-1005 — 135 m², 1 storey

Model 25-1005 • 135 m²

Model 25-1005 — 135 m², 1 storey

1 Storey
3 Bedrooms
0 Garage

Frequently Asked Questions

Essential answers regarding steel construction, energy targets and project delivery.

Yes. With exterior continuous insulation eliminating thermal bridging, certified triple-glazed windows, airtight membranes, and heat recovery ventilation (MVHR), steel homes achieve full Passive House standards.

Thermal bridging is prevented by external continuous insulation wrap, thermal-break tape on structural connections, and decoupling outer claddings from interior framing.

Passive House requires n50 <= 0.6 h-1 on Blower Door testing. Our envelope design incorporates continuous vapor control membranes taped at all seams.

Minergie is a Swiss quality label focusing on energy efficiency and indoor comfort with specific primary energy criteria, while Passivhaus has strict heating demand caps (15 kWh/m²a).

Official building certifications are issued by accredited third-party certifiers (e.g. Passive House Institute, Minergie Agency, DGNB) upon submission of calculations and test results.

Request a Project Quote

Prepare your project brief and connect directly with the SerVilla engineering team via WhatsApp.

Direct connection with SerVilla engineering desk.
ℹ️ How it works: Clicking opens a pre-composed project brief in WhatsApp. You review and send it yourself. No payment or financial data is collected.
Chat on WhatsApp