Country
Türkiye
Energy Framework
TS 825 Thermal Insulation Standard; BEP / NZEB Regulation
Verification Status
Verified Framework
Delivery Route
Supply + Supervision
Local Approvals
Local Registered Architect
Verified Framework

Steel Frame Homes in Türkiye: Standards & Guide | Passive Steel Homes

TS 825 addresses heating and cooling calculation; EKB energy documentation is a separate process.

Project Checklist for Türkiye

Confirm the site climate and current building requirements. Do not apply an NSEB area threshold to every villa.

Applicable Energy Standards & Certifications for Türkiye

Statutory building codes, government subsidy benchmarks, and voluntary green building certifications applicable in Türkiye:

3 Standards Mapped
International Gold Standard (PHI)

Passive House / Passivhaus

Passive House & Zero-Energy Buildings in Turkiye

A voluntary whole-building performance and certification route. Product certification and building certification have different scopes.

Explore Standard Details
Global Green Building Rating

LEED Residential / Homes

LEED Certified Energy-Efficient Villa Projects

A voluntary residential sustainability certification route covering energy and other building-quality topics. Eligibility and version must match the project.

Explore Standard Details
EU Directive Framework

nZEB and Zero-Emission Buildings

TS 825 & NSEB Nearly Zero-Energy Mandate

Nearly zero-energy and zero-emission buildings are different concepts. The EU transition includes 2028 for new publicly owned buildings and 2030 for all new buildings, subject to national implementation.

Explore Standard Details

States, Cantons & Regional Codes in Türkiye

Explore state-level building codes, regional climate zones, and local planning procedures:

7 Regions Listed
Marmara Region (Turkey) 7 Cities
TBDY 2018 (Turkish Seismic Code); TS 825 (Thermal Zone 2); BEP-TR; Ministry of Environment & Urbanisation

High-seismic zone (North Anatolian Fault) solutions using ultra-light gauge steel engineering with direct factory dispatch from Kocaeli.

View Regional Standards →
Aegean Region (Turkey) 5 Cities
TBDY 2018 (Western Anatolian Graben Faults); TS 825 (Zones 1 & 2); BEP-TR

Designed for intense Mediterranean sun and Western Anatolia seismic grabens: solar control glazing, external thermal blinds, rapid steel assembly.

View Regional Standards →
Mediterranean Region (Turkey) 5 Cities
TBDY 2018; TS 825 Zone 1 (Hot Mediterranean); BEP-TR

Cooling-load focused passive steel villas designed for high ambient humidity and scorching summers.

View Regional Standards →
Central Anatolia (Turkey) 5 Cities
TBDY 2018; TS 825 Zone 3 (Continental Climate); BEP-TR

Super-insulated passive steel homes engineered for extreme diurnal temperature swings and cold winters in Ankara, Konya and Eskişehir.

View Regional Standards →
Black Sea Region (Turkey) 6 Cities
TBDY 2018 (North Anatolian Fault Zone); TS 825 Zones 2 & 3; Landslide & Geotechnical Codes

Steep-slope foundation anchoring, corrosion-proof galvanized steel frames and waterproof facade systems for the rainy Black Sea coast.

View Regional Standards →
Eastern Anatolia (Turkey) 6 Cities
TBDY 2018 (NAF & EAF Fault Intersection); TS 825 Zones 4 & 5 (Extreme Cold)

Sub-zero engineering (-35°C), heavy snow load structural frames (>2.0 kN/m²) and triple-glazed passive shells for Eastern Turkey.

View Regional Standards →
Southeastern Anatolia (Turkey) 5 Cities
TBDY 2018 (East Anatolian Fault Southern Segments); TS 825 Zones 2 & 3

Engineered for 45°C+ summer heatwaves, dust tightness and rapid post-seismic reconstruction quality.

View Regional Standards →

Division of Responsibilities on Site

SerVilla Scope

Structural CFS framing production, building envelope insulation and weather barrier layers, assembly engineering, site supervision and logistics coordination.

Local Professional Scope

Building permit application, local planning approval, geotechnical survey and foundation slab execution, plus final local energy certification.

Türkiye Seismic & Multi-Climate Zone (TBDY 2018 / TS 825)

Climate Zone & Envelope Engineering for Türkiye

Superior seismic safety engineered with a CFS frame 6 to 8 times lighter than concrete (TBDY 2018 / Eurocode 8). Continuous exterior rockwool insulation and solar-controlled triple glazing prevent summer overheating across all climate zones.

Snow Load (sk)
sk = 0.75 – 2.00 kN/m² (TS 498 / EN 1991)
Wind Velocity (vb)
vb = 22 – 28 m/s (Regional Wind Zone)
Seismic PGA (ag)
ag = 0.20g – 0.50g (TBDY 2018 Ductile Frame)
Target Wall U
U <= 0.12 – 0.15 W/m²K (140mm Frame + 100mm Rockwool)
Target Roof U
U <= 0.09 – 0.11 W/m²K (300mm Cross-Laid Rockwool)
Glazing Specification
Triple Low-E Solar Control (g <= 0.35, Uw <= 0.80)
Foundation Perimeter
100mm Frost-Protected XPS Perimeter Skirt
Airtightness & MVHR
n50 <= 0.60 h⁻¹ • 85%+ Heat Recovery MVHR

U-Value & Performance Benchmarks for Türkiye

TS 825 Thermal Insulation Standard; BEP / NZEB Regulation

Target thermal transmittance values for cold-formed steel envelopes adapted to statutory benchmarks in Türkiye:

Building Element Statutory Baseline SerVilla Target
Exterior Wall U ≤ 0.18 – 0.24 W/m²K U ≤ 0.11 – 0.14 W/m²K
Roof / Attic U ≤ 0.14 – 0.20 W/m²K U ≤ 0.08 – 0.12 W/m²K
Windows & Doors Uw ≤ 1.00 – 1.30 W/m²K Uw ≤ 0.75 – 0.85 W/m²K (Triple Glazed)
Airtightness n50 ≤ 1.5 – 3.0 h⁻¹ n50 ≤ 0.60 h⁻¹
Ventilation Natural or Mechanical Exhaust ≥ 85% Heat Recovery MVHR

Logistics, Customs & Site Timeline for Türkiye

Factory-to-Site Dispatch
Transit Duration
1 – 2 Working Days
13.60m Flatbed / Curtain-side Truck (Factory Direct)
Customs & Documentation
Domestic Direct Factory Delivery (Türkiye): No customs clearance or import duties required; direct freight from SerVilla manufacturing plant to site.
Site Offloading
3-5 Ton Telehandler or Mobile Boom Crane
Superstructure Assembly
5-10 Working Days (SerVilla In-House Crew or Supervision)

Eurocode Structural Engineering, Snow, Wind & Seismic Safety in Türkiye

EN 1993 • EN 1998 • EN 1991

SerVilla cold-formed steel frames are engineered specifically for Türkiye in full accordance with Eurocode 3 (EN 1993-1-3), Eurocode 1 (site-specific snow & wind action maps), and Eurocode 8 (earthquake resilience). Fully verified calculation dossiers and 3D IFC models are supplied for local building control approval.

EN 1993-1-3
Cold-formed high-tensile S350GD galvanized steel structural sections.
EN 1991 (Kar & Rüzgar)
Site-specific snow drift and wind zone dimensioning of roof trusses.
EN 1998-1 (Sismik Dayanım)
6 to 8 times lighter than concrete, minimizing seismic inertia forces.
3D BIM & IFC Teslimi
100% interoperable IFC BIM models for local architects and energy consultants.

Plan Your Steel Frame Project in Türkiye

Discuss statutory requirements, insulation thicknesses and freight estimates with our international engineering desk.

Consult via WhatsApp

Energy Efficiency Grants & Subsidies in Türkiye

High-performance steel envelopes qualify for low-carbon grants and subsidized green mortgage schemes:

Zero-Emission Building (ZEB) Ready

Wall U-values down to 0.11 W/m²K cut primary energy demand by 50-70% below statutory baseline caps.

Green Mortgage Preferential Rates

Access preferential interest rates from European mortgage lenders for A+ EPC certified envelopes.

100% Recyclable Steel Framing

Fully aligned with EU Taxonomy circular economy directives with zero on-site construction waste.

High Value & 4-Season Climate Resilience

Featured Architectural Models for Türkiye

Continental & Southeastern European Zone

Three architectural concepts specifically engineered for Türkiye climate zone, statutory snow/wind actions (EN 1991) and envelope performance:

Model 25-1004 • Functional Single-Storey Home
25-1004 114 m² • 1 Fl

Model 25-1004 • Functional Single-Storey Home

Low initial capital investment with minimal heating overhead and zero factory waste.

CFS S350GD U ≤ 0.12 n50 ≤ 0.60
Explore Model
Model 22-2042 • Two-Storey Family Home
22-2042 100 m² • 2 Fl

Model 22-2042 • Two-Storey Family Home

Maximum living space on modest plots with Eurocode 8 seismic resilience.

CFS S350GD U ≤ 0.12 n50 ≤ 0.60
Explore Model
Model 25-2008 • Contemporary Family Residence
25-2008 195 m² • 2 Fl

Model 25-2008 • Contemporary Family Residence

Generous floor plan with dual-layer rockwool keeping interiors cool in summer and warm in winter.

CFS S350GD U ≤ 0.12 n50 ≤ 0.60
Explore Model

Official Code Sources

  • https://meslekihizmetler.csb.gov.tr/haberler/isi-yalitim-standardi-tebligi-guncellendi-290597
  • https://meslekihizmetler.csb.gov.tr/haberler/yeni-binalarda-yenilenebilir-enerji-zorunlulugu-yuzde-10-olacak-289813

Explore Other Model Concepts

Compare alternative footprints, storey options and spatial arrangements.

Important Note: Veranda, garage, terrace, pool, BASEMENT FLOOR, etc. are NOT included in areas & PRICES. Semi-detached / twin models: 1 unit basis.
Model 25-1003 — 99 m², 1 storey
Model 25-1003 Farmhouse & Ranch

Model 25-1003 • 99 m²

Model 25-1003 — 99 m², 1 storey

1 Storey
2 Bedrooms
1 Garage
Model 25-1004 — 114 m², 1 storey
Model 25-1004 American Style

Model 25-1004 • 114 m²

Model 25-1004 — 114 m², 1 storey

1 Storey
3 Bedrooms
1 Garage
Model 25-1005 — 135 m², 1 storey

Model 25-1005 • 135 m²

Model 25-1005 — 135 m², 1 storey

1 Storey
3 Bedrooms
0 Garage

Frequently Asked Questions

Essential answers regarding steel construction, energy targets and project delivery.

Each country has specific energy performance regulations (e.g. GEG in Germany, RE2020 in France, Part L in Ireland). We design our steel envelope to comply with your local code requirements.

Statutory permits, local planning submissions, and national structural certification must be signed by a registered local architect or engineer in your jurisdiction.

Steel frame kits and building materials are packed into shipping containers or trucks. Transport and customs clearance terms (Incoterms like DAP or CIF) are detailed in each quote.

Yes. We offer experienced erection supervisors who oversee local assembly teams to ensure structural alignment and airtight envelope execution.

Yes. For Scandinavian and Alpine regions, wall insulation thicknesses can be increased up to 300-400mm with U-values down to 0.10 W/m²K.

Request a Project Quote

Prepare your project brief and connect directly with the SerVilla engineering team via WhatsApp.

Direct connection with SerVilla engineering desk.
ℹ️ How it works: Clicking opens a pre-composed project brief in WhatsApp. You review and send it yourself. No payment or financial data is collected.